QuestionAnswer
Why is the Export report button dimmed or disabled?It is enabled only after a case finishes measuring on the measuring page. For older cases open the report from Case library › Open › A4 report.
Why is the Re-analyse button dimmed?No file has been chosen and there is no result yet. Choose a file or measure a case first.
Why can't I see the annotation tools on the measuring page?The Annotation block only appears after measuring and starts folded: click the Annotation block title in the left rail to open it, and the drawing toolbar appears along the left edge of the image. For multi-board comments use the Comment board.
How long are results and original files kept?Original files (HTML/STL) are kept for 7 days for re-measuring and 3D; the digests used by the comparison page for 90 days; scores, gates, rendered images and reports in the library forever, even after the plan expires.
Does batch measuring accept STL cases?Yes. On the Batch measuring page switch to STL, then drop up to 6 case folders (one folder per case), or click Choose folder / Choose loose files. A .constructionInfo in the same folder is attached automatically.
Do I have to upload the file again after changing settings?No. The run button becomes “Re-measure with new settings”; the server reuses the file it already has (within the 7-day retention).
Why is “Re-measure with other settings” dimmed in the library?The original file is past its 7-day retention and was deleted. Results, images and reports remain. To re-measure, upload the same file again on the measuring page — it costs no extra credit if it is the same file within 30 days.
Is a revision of the same case billed?No, if it is a re-export of the same exocad case within 30 days: the run is recorded as “revision of an earlier case — not billed”. Re-measuring the exact same file is free too.
Why does the overall score say “scored on x/y groups”?The overall score is the mean of the groups that have data. Groups without data (no material declared, no opposing arch, STL case missing files…) are left out rather than scored 0. Hover the line to see which groups counted.
Why is a high-scoring case still blocked?The export gate is a hard condition, not an average: one blocking item (hole in the mesh, wall below threshold, occlusal penetration…) blocks the whole case regardless of the score. The Export gate block tells which item and why.
Can editing scoring thresholds unlock a gate?No. The threshold table only changes scores; the export gate does not read a single row of it.
Why does wall thickness show a number but no score?No Restorative material is declared in the left rail. Without a material there is no threshold to judge by, and the thickness gate reads “not checkable”.
Why did my annotations disappear after re-measuring?Re-measuring rebuilds the projection, so old annotation coordinates no longer point at the right place; the app removes them and says how many. Export a PNG before re-measuring, or use the Comment board.
Do I lose my boards when I close the comment tab?Yes. Boards live only in that tab. Export the Board PNG, QC sheet PNG or merged image before closing.
The comment board says no case has been measured?“Get measured case” reads the latest measurement in THIS browser. Measure a case on the measuring page in the same browser, or paste an image with Ctrl+V.
Why does the comparison say “not two versions of one case”?The two runs share too few teeth for a difference to mean anything. Check that you dropped the before and after files of the same case.
Why is 3D side by side dimmed?It needs the original files of BOTH runs. Originals are kept for 7 days; the number table still works because it reads the digests.
Why does the comparison show things getting worse when nobody changed anything?Usually the two runs used different tolerance profiles or settings, or the tooth set changed. Read the warnings above the table; measure both on the comparison page so they share one settings set.
An STL case has stations marked “measured but not scored”?The case lacks files that station needs (die, antagonist, ridge scan) or the meshes are solid or not in one coordinate system. Drag the whole case folder and export the scans too; the hint box lists which file unlocks which station.
The app cannot read the tooth number of an STL file?Rename the file with the tooth number (for example Crown 11.stl) or drop the case's .constructionInfo along, then upload again.
What happens when today's slots are used up?The free plan limits new cases per day. Re-measuring cases already measured still works; new cases wait until tomorrow, or upgrade/buy credits on the Plan page.
A batch stopped halfway?A batch stops by itself only when the session expires, the plan/quota runs out or the server runs out of disk; the reason shows on the “Not measured” rows. Fix the cause and click Measure again — finished cases are not measured twice.
I paid by bank transfer but the plan is not on?Open Orders and check the status. “Paid, activating” usually finishes within minutes; “received only X” means an underpayment. If nothing is recorded after 30 minutes, send the reference code with a photo of the receipt.
Why can't I edit thresholds?The Free plan does not allow custom thresholds. On the Lab plan the thresholds are a shared set that only owners/admins can edit; everyone else sees it read-only.
Why can't I see my colleagues' cases?The owner turned off “Members can see each other's cases” in Profile. When off, each member only sees their own cases; owners and admins always see everything.
How do I save the report as PDF?Open the A4 report, click “Print / Save as PDF”, then choose the “Save as PDF” printer in the print dialog. A4 size and page breaks are preset.
Does switching language lose my results?No. On the desks, switching the VI/EN flag happens in place without reloading the page.
Why does the app ask FDI / Universal / Palmer?The prescription uses tooth numbers the app cannot place in one system. A wrong guess raises no error, so the app asks instead; click one button in the question box under the Prescription field.
How do I throw out someone sharing my account?Go to Profile › Password and change the password: every other session ends immediately, except the one you are using.
Copy sheet to clipboard says it was blocked?The browser does not let the page write to the clipboard. Use Viewport PNG or QC sheet PNG and send the image file.
The 3D model will not open?The browser has no usable WebGL, or the original file has passed its retention. The 2D views and number tables keep working.
A file is too large to upload?The server has an upload size limit; an STL case can total at most 80 MB. For webviews, re-export the file or contact the server administrator.