DentalQC › Docs › Frequently asked questions
Frequently asked questions
Short, direct answers about what DentalQC measures, which files it reads, how it scores a case and what it costs.
What is DentalQC?
DentalQC is a web tool for dental technicians that measures exocad and STL dental designs in real millimetres across 7 QC stations: wall thickness, connector cross-section, occlusion, path of insertion, symmetry and a prescription cross-check. It scores 94 metrics against thresholds your lab sets, points at exactly what to fix, and proves it when the revision comes back. The Free plan measures one case a day.
How do I check the wall thickness of a zirconia crown designed in exocad?
Export the webview HTML from exocad, drop it on the DentalQC measuring page and declare the material as zirconia. DentalQC measures axial, occlusal and margin wall thickness on the real mesh, colours every area thinner than the material minimum and blocks export when a wall is below it. Defaults for high-strength zirconia (3Y) are 0.5 mm axial, 0.7 mm occlusal and 0.3 mm at the margin; check them against your blank manufacturer's instructions.
What is the minimum connector cross-section for a zirconia bridge, and how does DentalQC measure it?
DentalQC's defaults are 7 mm² for anterior and 9 mm² for posterior connectors in high-strength zirconia (3Y), and 9 mm² / 12 mm² in esthetic 4Y/5Y zirconia. It finds the smallest cross-section of each connector directly on the bridge mesh and scores it against the threshold of the declared material. These are material guidelines, not a clinical prescription — confirm them against the blank lot you mill.
Does DentalQC work with 3Shape or only exocad?
DentalQC reads two kinds of input: the webview HTML that exocad exports, and the loose STL files of a case, exported from exocad or 3Shape. There is no direct 3Shape plug-in. STL files carry no tooth numbers or roles, so DentalQC infers them from file names and sizes; check the role list before relying on the score, and include the antagonist and die scans to unlock every station.
What file do I export from exocad for DentalQC?
Export the webview HTML — the 3D web-viewer file exocad makes for sending a design to a dentist. It already contains the full 3D mesh in millimetres, so no screenshots and no scale calibration are needed. Add the case's .constructionInfo file if you have it: it carries tooth numbers, materials and order details that station 01 compares with the prescription.
Is my case data uploaded anywhere?
Files are processed on DentalQC's own servers (Singapore); nothing is sent to third-party analysis services. Original files are deleted after 7 days. Scores, gates, rendered images and reports stay in your case library for as long as your plan keeps history. Labs that cannot let prescriptions leave their network can ask about the on-premise plan, which runs inside the lab.
How accurate are the measurements?
As accurate as the design file itself. exocad stores coordinates in millimetres, so DentalQC measures the real geometry — no screenshots, no scale calibration, no re-scanning. Results follow the mesh resolution you export. Anything without enough data is marked “not checkable” instead of being guessed, and default thresholds are population norms or material guidelines that your lab can tighten.
What does the QC score mean, and how is the A–E grade decided?
The QC score (0–100) is the mean of the measurement groups that have data; a measurement costs nothing below its ideal threshold and everything at its fail threshold. The grade follows the score: A 92 or more, ready to deliver; B 84–92, light touch-up; C 72–84, correct before milling; D 60–72, revise the design; E below 60, redesign. Groups without data are left out, never scored 0.
What is the export gate, and why is a high-scoring case “blocked”?
The export gate is a hard pass / hold / block check that runs separately from the score. One blocking item — a hole in the mesh, a wall below the material minimum, occlusal penetration, a feature smaller than the smallest bur — blocks the whole case even when it scores 95. Editing scoring thresholds never unlocks a gate; the gate block names the item and the reason.
How much does DentalQC cost? Is there a free plan?
Yes. The Free plan measures 1 case a day with an unlimited comment board and needs no card. Paid plans: Solo $17 / month, Duo $30 / month, Lab $140 / month. Paid plans count cases, not measurements: every revision of the same case within 30 days is free. Labs billed in Vietnam can also pay per case (15.000 ₫ a case).
Can I set my own tolerances?
Yes, on paid plans. Each of the 94 metrics has an ideal and a fail threshold you can set: Solo and Duo users set their own, and on the Lab plan the owners set one shared table for the whole lab. The Free plan scores with the default table, which stays readable in full. Thresholds change scores only — they never unlock the export gate.
Can I compare two versions of the same case?
Yes, from the Solo plan up. On the comparison page drop the before and after files of the same case; DentalQC measures both with one shared set of settings and lists, measurement by measurement, what improved and what got worse, with a 3D side-by-side while both originals are kept (7 days). A revision of the same exocad case is not billed as a new case.
Is DentalQC a medical device?
No. DentalQC is a CAD geometry measurement tool for dental technicians, not a medical device. Every reference value in it is a population norm, a material guideline or a threshold your lab declared — never a clinical prescription for an individual patient — and it does not replace clinical judgement.
Does DentalQC have a mobile app?
Yes — an iPhone app is included with every paid plan at no extra cost. It shows the same score, the same seven stations, the A4 report and the 3D model, and notifies you when a case is blocked or a designer replies. Each seat gets one web session and one phone session, so opening the app does not sign you out of the computer. The Free plan works in the browser.
How do I measure many cases at once?
Use Batch measuring: drop up to 6 exocad webview files or STL case folders (one folder per case) and DentalQC measures them one after another with the same settings. Each case lands in the case library with its own score, gate and report, a .constructionInfo in the same folder is attached automatically, and restarting a batch never measures a finished case twice.