Seven QC stations and the export gate

The score ranks; the gate is a door. A case can score high and still be blocked.

01

Prescription check

Compares the file with the order slip: case ID, dentist and signature date, requested teeth, restoration type, material and any measurable targets. Without a prescription station 01 cannot turn green, but every other geometric measurement still runs.

02

Preparation & margin

Reads the quality of the die scan and the margin line: roughness, and how well the restoration rim fits the die surface. Without a die scan, or for restoration types that have no preparation, only the measurements with data appear.

03

Restoration intaglio

Measures wall thickness, areas thinner than the material threshold, undercuts and the insertion axis. If no material is declared, thickness is still shown but not scored.

04

Contacts & connectors

Measures proximal contact gaps and penetration, the bucco-lingual contact position, connector cross-sections and pontic-to-ridge seating. Connectors are scored only when a matching material or threshold is available.

05

Static & dynamic occlusion

Measures overjet, overbite, occlusal penetration, posterior contact points, the curve of Spee, anterior Bolton, molar relationship and excursion checks such as non-working-side interferences. Both arches are needed for the full check.

06

Form & esthetics

Measures symmetry, anterior proportions, midline, smile line, lateral incisor step, gingival contour, cusp count, marginal ridges, central fossa, height of contour and occlusal table width.

07

Manufacturability & export

Checks mesh health, holes, loose shells, flipped faces, self-intersections, features smaller than the tool, and the hard gates before export or milling. This check is independent of the scoring threshold table.

Station states

  • scored: the station has enough data and counts towards the score.
  • partial: only some of the station's measurements have data.
  • measured, not scored: figures for reference that add nothing to the score (for example no material declared, STL case missing files).
  • not available: the station cannot be measured with the current data.

Export gate (ready to export)

Gates are hard conditions before export or milling, not an average score. Each item has four states: pass, hold (needs a person to decide), block (fix before export) and not checkable (read carefully before signing off). The scoring threshold table does not unlock a gate.

CodeDisplayed labelMeaning
meshWatertight, sane meshThe mesh must be closed and healthy for its object type; holes, loose shells, flipped faces and self-intersections are CAM risks.
toolNothing finer than the burThe smallest tool must reach concave details after the material enlargement factor is applied. 3–8% of the area out of reach is a hold, above 8% a block; no tool declared means not checkable.
thickWall thickness over the minimumWall thickness must stay above the material threshold, or the constructionInfo threshold. No material declared means not checkable.
indicMaterial indicationThe chosen material product must be indicated for the restoration: type, number of units, pontics in a row, cantilever and region. A product not yet checked against its IFU is a hold; no product chosen means not checkable.
seatSeats on the preparationThe inner surface must not cut into the preparation, and your lab's bur must reach the intaglio (3–8% unreached is a hold; above 8% with more than 0.15 mm left is a block). A bur larger than the design was compensated for is a hold.
connConnector cross-section over the minimumConnectors must meet the minimum cross-section for the material and the anterior/posterior position.
implantImplant restorationImplant units: the screw channel must not break through the wall, the channel body wall must be at least 0.30 mm, the crown must not cut into the Ti-base, a straight channel must stay on the implant axis and an anterior access must not open on the facial or incisal edge. A screw head wider than the channel, a wall below the design value or a library/Ti-base mismatch is a hold.
occlNo occlusal interpenetrationThe design must not penetrate the opposing arch. A file with only one arch is not checkable.
contactNo open proximal contactProximal contacts must not be open beyond the checked limit (0.10 mm).
blankFits your blanksEach unit or bridge must fit one of the discs or blocks your lab listed in Settings › Milling machine (height, flat or tilted; disc diameter). Size only — nesting and sprues are still checked in CAM. Nothing listed means not checkable.
namingRight file, right namesObjects must be named, not truncated, and no required unit may be missing.