DentalQC › Docs › Prescription (station 01) and the .constructionInfo file
Prescription (station 01) and the .constructionInfo file
Station 01 answers the question that comes before all others: is this the design that was ordered. It gives no score; it gives a pass / block / not-checkable gate.
Pasting the prescription
- One box, taken verbatim: email, order form, chat message. No tidying up and no form to fill in.
- The parser reads: case code, dentist/signature date, the teeth to make (including ranges like
14-25that cross the midline), restoration type, material and measurable targets (for example central incisor length, canine guidance, tooth form). - Measurements with units (for example “increase VDO 3-4mm”) are separated first so they are not misread as teeth 3 and 4.
- Readable targets become verdicts: checkable ones are compared directly with the measurement; ones needing a baseline (like a VDO increase) read “not checkable” with the reason; exceptions (for example a diastema allowed) switch off exactly the related key on exactly those teeth and show the quote.
- Lines it does not understand are reported, and while any line is unread the station never reports “clean”.
- When the prescription names a material for every unit and only one material, stations 03/04/07 take their thresholds from it instead of the manual selector.
- The parser deliberately does not extract patient names, only a case code.
- Without a prescription station 01 is not green, but every other geometric measurement still runs. Batch measuring has no prescription box, so station 01 stays empty there.
Tooth numbering system
- There is no default: on a US slip “8” is tooth 11 and “14” is tooth 26, and both are valid FDI codes, so a wrong guess raises no error.
- The app only decides on its own with decisive evidence (for example numbers 33–48 cannot be Universal). Otherwise the FDI / Universal / Palmer question appears with both readings — one click answers it.
The .constructionInfo file
- The XML file exocad writes next to every saved case, in the same folder as the webview file. Click Drop .constructionInfo in the Prescription block to pick it (in STL mode it can be dropped together with the .stl files).
- It is not a prescription: it is the design software's own as-built declaration, so checking against it always matches. It serves to pre-fill the slip and to supply
MinThicknessandMillingDiameter. - If the bur box is empty, the bur diameter is taken from the file. The readout also reports the cement gap, how many teeth declare a margin line, and warns when the file's tooth set disagrees with the design (one of the two files is not from this case).
- Files that are abnormally large, empty, not valid XML, or contain no teeth or parameters are rejected with the reason.
- Click × to remove the file; later re-measures will stop using it.