DentalQC › Docs › Measuring cases delivered as STL
Measuring cases delivered as STL
Besides exocad HTML webviews, the app measures cases delivered as loose STL files (exocad or 3Shape). STL carries no role names, tooth numbers or shared coordinate system, so the app infers them from file names and sizes.
Getting the files in
- On the measuring page switch to STL, then drag the whole case folder onto the drop zone or click Choose case folder. Pick the crowns, dies, jaw scans and antagonist in one go.
- For exocad: the case folder holds files like
…-11-crown_cad.stland the.constructionInfo. For 3Shape: select all .stl files of the case. - To score the intaglio and occlusion, also export the die/jaw scans and the antagonist.
- One case may total at most 80 MB.
Automatic role assignment
- Each file's role (restoration, die, scan, antagonist…) is inferred from its name and size; the role list appears in the result — check it before reading scores.
- Tooth numbers come from file names; names without a number fall back to the
.constructionInfo. If none can be inferred the file stays out of the measurement — rename it with the tooth number (for exampleCrown 11.stl). - A name that says single unit on a full-arch-sized file is treated as a scan, and the reverse raises a warning.
- A longest edge that does not look anatomical usually means the file was exported in inches or cm — STL stores no unit, so every measurement would be off by the same factor.
Measurable stations and “measured but not scored”
- At least 3 restoration units with tooth numbers are needed to build the anatomical frame; with fewer, no station can be measured.
- No die file → the preparation & margin station is not measured. No antagonist → occlusion is not measured. No gingiva/ridge scan → the pontic-to-ridge relation is not measured.
- Solid meshes (no hollow) → the figure is solid thickness, not wall thickness.
- Files not in the same coordinate system → figures between two objects are computed but meaningless.
- When the data is not a sound basis, the station still shows figures for reference but says “measured but NOT scored” and adds nothing to the overall score. The hint box lists which missing file unlocks which station.
- A closed mesh welded at the rim has no detectable margin — drop the
.constructionInfoalong to get the margin line.