Walls too thin
Thickness per region, measured by rays through the material, against the minimum for the blank you declared.
DentalQC reads the real geometry in your exocad webview or STL case and measures it in millimetres: 94 metrics in 13 groups, checked at 7 QC stations, each metric with its own ideal and fail threshold. A separate export gate stops a case that must not be milled, whatever its score.
Six families of defect that only surface after milling — or worse, after it is in the patient.
Thickness per region, measured by rays through the material, against the minimum for the blank you declared.
True cross-section in mm² at the narrowest point — the one number with a published manufacturer minimum.
Overjet, overbite, interpenetration, a clearance map, and whether the posteriors disclude in protrusion.
Undercut and path of insertion on the intaglio surface. However good the fit, an undercut still blocks it.
Each pair of matching teeth mirrored, width-to-length ratio, smile arc and gingival contour against reference norms.
Paste the prescription in and the app cross-checks tooth numbers, unit count and restoration type.
Every case goes through the same seven stations, in the order a careful QC reviewer would check it.
Compares the file with the order slip: case ID, dentist and signature date, requested teeth, restoration type, material and any measurable targets. Without a prescription station 01 cannot turn green, but every other geometric measurement still runs.
Reads the quality of the die scan and the margin line: roughness, and how well the restoration rim fits the die surface. Without a die scan, or for restoration types that have no preparation, only the measurements with data appear.
Measures wall thickness, areas thinner than the material threshold, undercuts and the insertion axis. If no material is declared, thickness is still shown but not scored.
Measures proximal contact gaps and penetration, the bucco-lingual contact position, connector cross-sections and pontic-to-ridge seating. Connectors are scored only when a matching material or threshold is available.
Measures overjet, overbite, occlusal penetration, posterior contact points, the curve of Spee, anterior Bolton, molar relationship and excursion checks such as non-working-side interferences. Both arches are needed for the full check.
Measures symmetry, anterior proportions, midline, smile line, lateral incisor step, gingival contour, cusp count, marginal ridges, central fossa, height of contour and occlusal table width.
Checks mesh health, holes, loose shells, flipped faces, self-intersections, features smaller than the tool, and the hard gates before export or milling. This check is independent of the scoring threshold table.
Each metric has an ideal and a fail threshold. Below ideal costs nothing, at fail it costs everything, in between it costs proportionally. Groups without data are left out instead of being scored 0.