Restorative material
If no material is declared, the app still measures thickness, connectors and related areas, but it does not score items that need material thresholds. The default thresholds must be checked against the IFU of the blank lot in use.
Smallest bur
Available choices: 0.6 mm, 1 mm, 1.5 mm, 2 mm, 2.5 mm. Zirconia applies the enlargement factor when converting the tool radius into design coordinates (pre-sintered blanks are milled oversize).
| Material | Axial wall | Occlusal/incisal | Margin | Anterior connector | Posterior connector | Blank factor |
|---|---|---|---|---|---|---|
High-strength zirconia (3Y)zr_hs |
0.5 mm | 0.7 mm | 0.3 mm | 7 mm² | 9 mm² | ×1.25 |
Esthetic zirconia (4Y/5Y)zr_est |
0.8 mm | 1 mm | 0.5 mm | 9 mm² | 12 mm² | ×1.25 |
Lithium disilicate (e.max)lidi |
0.8 mm | 1 mm | 0.5 mm | 12 mm² | 16 mm² | ×1 |
Bonded ceramic veneerveneer |
0.3 mm | 0.4 mm | 0.25 mm | — | — | ×1 |
PMMA / temporary resinpmma |
1 mm | 1.5 mm | 0.5 mm | 10 mm² | 12 mm² | ×1 |
Cast metal / CoCrmetal |
0.3 mm | 0.5 mm | 0.3 mm | 4 mm² | 6 mm² | ×1 |
Composite / printed resincomp |
1 mm | 1.5 mm | 0.5 mm | 10 mm² | 12 mm² | ×1 |